For decades, our high-quality vapour recovery pumps have been ensuring safe and economical use at petrol stations worldwide. Whether belt or direct drive, classic proportional valve or modern electronic speed control - we will be pleased to advise you on the various models.
The new product series "MEX Vapour Control" is based on a direct drive and has an electronic speed control. The electronic speed control ensures that petrol vapour’s are optimally extracted and at the same time reduces mechanical wear and tear on the engine and other mechanical components, as these only deliver maximum performance when required. This ensures better energy efficiency and a longer service life. Due to the electronic speed control the proportional valve is no longer required.
This technological innovation provides you with a comprehensive vapour recovery solution for use in the petrol pump. At the same time, you are relying on a very durable vapour recovery pump, which offers a great deal of potential for the "Smart Solution" of tomorrow.
The all in one solution for your petrol dispenser.
The vapour recovery pump MEX Vapour Control consists of a particularly compact MEX direct drive 1-cylinder and a frequency converter, which controls the speed of the motor during vapour recovery.
For the installation and calibration of the vapour recovery system the software "DürrTronic MEX-Soft" is available to customers free of charge.
Special advantages of the vapour recovery pump MEX Vapour Control:
Electrical data | ||||||||
Type | Flow volume |
End pressure |
Relay |
Rated current |
Nominal voltage |
Frequency |
Frequency converter |
Dimensions |
V (l/min) | (mbar) | (V) | (A) | (V) | (Hz) | (V) | L x Wx H (mm) | |
0544100200 with VFD 0545100001 |
42 at 1800 rpm | <300 | without | 0,65 | 230 3~ | 50 | 230 1~ | 232 x 160 x 209 |
Remarks:
V = Volume flow at back pressure pe = 150 mbar and a suction pressure pabs = 900 mbar
Sound level < 70 dB(A)
pabs = absolute pressure
For use in dispensers with only one dispensing side.
Electrical data | |||||||
Type | Flow volume |
End pressure |
Relay |
Rated Current |
Nominal voltage |
Frequency | Dimensions |
V (l/min) | (mbar) | (V) | (A) | (V) | (Hz) | L x W x H (mm) | |
3~Motor 50 Hz |
|||||||
0544 1000K | 53 | <300 | 24 DC | 0,75 | 380-415 | 50 | 312 x 174 x 201 |
0544 1100K | 53 | <300 | without | 0,75 | 380-415 | 50 | 312 x 174 x 201 |
0544 1700K | 53 | <300 | 220-240 AC | 0,75 | 380-415 | 50 | 312 x 174 x 201 |
1~Motor 50 Hz |
|||||||
0544 1200K | 53 | <300 | 24 DC | 2,30 | 220-230 | 50 | 367 x 174 x 201 |
0544 1250K | 53 | <300 | 220-240 AC | 2,30 | 220-230 | 50 | 367 x 174 x 201 |
0544 1300K | 53 | <300 | without | 2,30 | 220-230 | 50 | 367 x 174 x 201 |
1~Motor 60 Hz |
|||||||
0544 1400K | 44 | <300 | 24 DC | 1,80 | 110-127 | 60 | 367 x 174 x 201 |
0544 1800K | 38 | <300 | without | 1,15 | 220 | 60 | 367 x 174 x 201 |
Remarks:
V = volume flow at back pressure pe = 150 mbar and a suction pressure pabs = 900 mbar
Noise level < 70 dB(A)
pabs = absolute pressure
For use in dispensers with two dispensing sides.
Electrical data | |||||||
Type |
Flow volume |
End pressure |
Relay |
Rated current |
Nominal voltage |
Frequency | Dimensions |
V (l/min) | (mbar) | (V) | (A) | (V) | (Hz) | L x W x H (mm) | |
3~Motor 50 Hz |
|||||||
0544 2000K | 53 | <300 | 24 DC | 1,0 | 380-415 | 50 | 434 x 174 x 201 |
0544 2100K | 53 | <300 | without | 1,0 | 380-415 | 50 | 434 x 174 x 201 |
0544 2700K | 53 | <300 | 220-240 AC | 1,0 | 380-415 | 50 | 434 x 174 x 201 |
1~Motor 50 Hz |
|||||||
0544 2200K | 53 | <300 | 24 DC | 3,0 | 220-230 | 50 | 489 x 174 x 201 |
0544 2250K | 53 | <300 | 230 AC | 3,0 | 220-230 | 50 | 489 x 174 x 201 |
0544 2300K | 53 | <300 | without | 3,0 | 220-230 | 50 | 489 x 174 x 201 |
1~Motor 60 Hz |
|||||||
0544 2400K | 44 | <300 | 24 DC | 2,9 | 110-127 | 60 | 489 x 174 x 201 |
0544 2800K | 38 | <300 | without | 1,7 | 220 | 60 |
489 x 174 x 201 |
3~Motor 60 Hz |
44 | <300 | 24 DC | 1,2/0,7 | 230/400 | 60 | 434 x 174 x 201 |
Remarks:
V = volume flow at back pressure pe = 150 mbar and a suction pressure pabs = 900 mbar
Noise level < 70 dB(A)
pabs = absolute pressure
For the mobile filling station.
Electrical data | |||||||
Type | Flow volume |
End pressure |
Relay |
Rated current |
Nominal voltage |
Frequency | Dimensions |
V (l/min) | (mbar) | (V) | (A) | (V) | (Hz) | L x W x H (mm) | |
0544100096* | 53 | <300 | 12 DC | 20 | 12 DC | – | 423 x 176 x 201 |
0544100152 | 53 | <300 | 24 DC | 13 | 24 DC | – | 423 x 176 x 201 |
Remarks:
V = volume flow at back pressure pe = 150 mbar and a suction pressure pabs = 900 mbar
Noise level < 70 dB(A)
pabs = absolute pressure
* Coming soon.
Type | Flow volume | End pressure | Recommended motor power | Max. permissible speed of rotation | Dimensions |
V (l/min) | (mbar) | (W) | (1/min) | L x W x H (mm) | |
0831-11/600 | 44 | ˜ 150 | 150 (200) | 2300 | 117 x 88 x 188 |
Accessory: belt pulley (94 mm effective diameter) on request.
Remarks:
V = volume flow at back pressure pe = 150 mbar and a suction pressure pabs = 900 mbar
Noise level < 70 dB(A)
pabs = absolute pressure
Why not become an official, certified Dürr Technik MEX service partner and enjoy all the benefits of our support?
Your benefits:
Request information now and become a MEX service partner.